9Group 3: Language for Keyboard InterfaceENTER GROUPU.S. (*)ENGLANDFRANCEGERMANYITALYBELGIUMSWEDEN/FINLANDSPANISHDENMARKPORTUGALSWISSNORWAYEXIT
10Group 3: Language for Keyboard InterfaceENTER GROUPCANADAHOLLANDPOLANDLATINJAPAN1Reserved2Reserved3Reserved(IBM THINK-PAD FOR JAPAN)(PANASONIC CF-FO
11Group 4: TerminatorKEYBOARDENTER GROUPNONECR(*)SPACETABESCCTRL-CEXECEXIT
12Group 4: TerminatorRS-232ENTER GROUPEXITNONECR (*)CR/LFLFSPACETABESCCTRL-CSTX..ETXXON.. XOFFEOT
13Group 5: Scan ModeENTER GROUPEXIT1: Trigger On/Off2: Trigger On/Good Read Off (*)3: Trigger On/Good Read Off/Delay Timeout = ?4: Continuous/Trigger
14Group 5: Scan ModeENTER GROUPEXITFLASH OFF(*)FLASH ONNote: Scan mode setting is only available forLaser type scanner.CCD/
PreamblePostamblePreamble & Postamble Setting:Scan Enter Group 6 Label -->Scan Preamble or Postamble Label -->Refer to ASCII Table(page 46),
16Group 7: RS-232 ParametersBaud RateData BitEXITBIT 7BIT 8 (*)ENTER GROUP120048001920060024009600(*)38400
17Group 7: RS-232 ParametersParity :Handshaking:EXITNONE (*)ODDEVENNONE (*)XON/XOFFScanner ReadyData ReadyACK/NAKENTER GROUP
18Group 7: RS-232 ParametersEXIT100 ms300 ms500 ms1 sec5 sec10 sec3 sec (*)00ENTER GROUP(ACK/NAK Response TimeCTS Observation Time:)
1Getting Started ... 2Setup Procedures ...
19Group 8: CODE 39 / CODE 32EXITStandard (*)Full ASCIITransmit Start/End CharacterCode 39Disable (*)EnableTransmit Check CharacterVerify ChecksumENTER
20Group 8: CODE 39 / CODE 32EXITVerify Normal (*)Verify StrickDisable CODE 32 (*)ENTER GROUPEnable CODE 32
21Group 9-1: Interleaved 2 OF 5EXITTransmit Check CharacterDisableEnable (*)Verify ChecksumDisable (*)EnableLength DefineMin: 4Max: 48Scan Enter Group
22Group 9-2: Industrial 2 OF 5 / IATAEXITTransmit Check CharacterTransmit Check CharacterIATADisableDisable (*)Enable (*)EnableENTER GROUPLength Defin
23Group 9-3: Matrix 2 OF 5EXITTransmit Check CharacterVerify ChecksumLength DefineMin: 2Max: 40Scan Enter Group 9-3 Label -->Scan Length Define Lab
24Group 9-4: CHINA POSTAGEEXITTransmit Check CharacterVerify ChecksumLength DefineMin: 2Max: 40Scan Enter Group 9-4 Label -->Scan Length Define Lab
25Group 10: Code 128EXITEnable/Disable CheckdigitDisableNote: Options marked by ( ) are only available upon requestENTER GROUPDisableEnable (*)Disable
26Group 11: CODE 11EXITEnable/Disable CheckdigitNumber of Check CharacterTransmit Check CharacterTwo (*)OneENTER GROUPEnable (*)DisableEnableDisable (
27Group 12: Code 93EXITENTER GROUPVerify CheckdigitDisable (*)EnableEnable (*)Disable
28Group 13: MSI-PLESSEYEXITVerify CheckdigitEnable MODTransmit/Truncate CheckdigitEnable MOD 11-10Truncate 1 & 2 checkdigitst ndEnable MOD 10 (*)T
2Getting StartedTo install a keyboard wedge barcode scanner, follow the stepslisted below:1) Make sure that the scanner has the correct Y (U)-cable fo
29Group 14: CODABAR / NW7EXITDisableDisable (*)Enable (*)EnableABCD/ABCDABCD/TN*Eabcd/abcd (*)abcd/tn*eENTER GROUPTransmit Start/End CharacterStart/En
30Group 15: Code 4EXITDisable (*)EnableENTER GROUP
Enable (*)31Group 16-1: EAN-13/JAN-13EXITENTER GROUPDisableEnable (*)Disable (*)EnableADD-ON 2/5DisableEnable (*)Transmit Check CharacterDisable (*)En
32Group 16-2: UPC-AEXITENTER GROUPDisableEnable (*)Disable (*)DisableDisable (*)EnableEnable (*)EnableADD-ON 2/5Transmit Check CharacterTruncate Leadi
33Group 16-3: EAN-8/JAN-8EXITENTER GROUPDisableEnable (*)Disable (*)DisableDisable (*)Disable (*)EnableEnable (*)EnableEnable 1(add zeros in the front
34Group 16-4: UPC-EEXITENTER GROUPDisableEnable (*)Transmit Check CharacterDisable (*)EnableTruncate Leading DigitDisable (*)EnableUPC-E Convert to UP
35Group 16-5: ISBN/ISSNEXITENTER GROUPDisable (*)Enable
36Group 17: General ParametersEXITENTER GROUPBuzzer Pitch(Default : 21)Buzzer Duration(Default: AA)Buzzer Pitch & Buzzer Duration Setting:Scan Ent
Group 18: Code ID SettingEXITENTER GROUPCODE 39/CODE 32INTERLEAVED 2 OF 5INDUSTRIAL 2 OF 5MATRIX 2 OF 5CHINA POSTAGECODE 128CODE 93CODE 11MSI/PLESSEYC
38Group 19: WAND Type ParametersEXITENTER GROUPBAR=LOWBAR=HIGH(*)LowestLow (*)HighHighestData FormatTransmit in Normal Format (*)Transmit in Code 39 F
3Barcode Scanner Setup Procedures1) Locate a group that contains the parameters to bechanged.2) Scan the "Enter Group #" label. The scanner
39Group 20-1: (Magnetic Parameters)EXITENTER GROUPDisableEnable (*)Track 1/2/3 (*)Track 1/3/2Track 2/1/3Track 2/3/1Track 3/2/1Track 3/1/2Note: Options
40Group 20-1: (Magnetic Parameters)EXITENTER GROUPTrack 1&2&3 any (*)Track 1 onlyTrack 2 onlyTrack 3 onlyTrack 1 and 2Track 2 and 3Track 1 and
41Group 20-2: (Magnetic Parameters)EXITENTER GROUPTk1 Default : %Tk2 Default: ;Tk3 Default: ;Tk1 Default : NullTk2 Default: NullTk3 Default: NullTk1&a
42Group 21: (Function Key Emulation)EXITENTER GROUPEnableEnable Function Key Emulation:Scan Enter Group 21 Label -->Scan Enable Label -->Scan Ex
Function Code for PC XT/AT43F1 ($A)F7 ($G)F2 ($B)F8 ($H)F3 ($C)F9 ($I)F4 ($D)F10 ($J)F5 ($E)F11 ($K)F6 ($F)F12 ($L)
Function Code for PC XT/AT44Enter ($M)End ($U) ($B)Tab ($N)PgUp ($V)BS ($O)PgDn ($W)Up ($P)Ins ($X)Down ($Q)Del ($Y)Left ($R)Esc (%A)Right ($S)Home ($
Table-Hex : HEXADECIMAL450123456789ABCDEFConfirm
ASCII TABLE46H/I 0 1 2 3 4 5 6 70 NULL DLE SP 0 @ P ` p1 SOH DC1 ! 1 A Q a q2 STX DC2 " 2 B R b r3 ETX DC3 # 3 C S c s4 EOT DC4 $ 4 D T d t5 ENQ
H/I 0 1 2 3 4 5 6 7 8 9 A B C D E F0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 151 1617 18 19 20212223 2425 26 2728 2930 312 3233 34 35 36373839 4041 42 4344
16Function DB9F Din6M/5M(240 )Start of Scan 1 6Signal Data 2 2Led Indicator 3 ---Trigger 5 5Power Enable 6 4GND 7 3VCC+5V 9 110Pin Modular PlugTTL Sig
4ENTER GROUPSetup Flow ChartSELECT ITEMSEXITSet All DefaultsShow VersionNote: (*) denotes default setting options marked by ( )only available upon req
Wand Emulation Signal OutputRS-232 Signal OutputFunction DB9F Din5M Din6M/Din5M(180 ) (240 )Signal Data 2 1 2GND 7 2 3VCC+5V 9 3 1Note : "F"
Keyboard Signal OutputFuncion Din5F Din5M Mini-Din6M Mini-Din6FGND 4 4 5 5PC_Data --- 2 --- 4PC_CLK --- 1 --- 6Vcc+5V 5 5 2 2KB_CLK 1 --- 6 ---KB_Data
V20040930
5Group 0: Interface SelectionKEYBOARDENTER GROUPEXITRS-232(WAND)(OCIA)(DTMF)Reserved 2Resered 3Reserved 4Note: The interface is pre-set at factory acc
6Group 1: Device Selection for Keyboard InterfacePC/AT, PS/2 50,60,70,80(*)PC/XTPS/2 25, 30(NEC 9801)(IBM 5550)(PS 55)(NEC N5520)(ACER 7300)(KW105D/CT
7Group 1: Device Selection for Keyboard InterfaceENTER GROUPEXIT(IBM3196, 3197, 3476, 3477)Reserved 8Reserved RIBM3197IBM3477Reserved 6Reserved Q9Rese
8Group 2: Intercharacter DelayENTER GROUPStart Keyboard SettingScan Enter Group 2 Label -- >Scan Start Keyboard (or RS-232) Setting Label -->Sca